3-D Touch Probes for Workpiece Setup
and Measurement
TS
220, TS 230 and TS 632 |
|
|
The TS
is a 3-D touch trigger probe for workpiece setup,
measurement and identification, as well as for the digitizing
of workpieces in the working space of a machine tool. The
trigger signal is formed through a highly reliable, wear-free
optical sensor.
Workpiece Setup
The 3-D touch probes from
HEIDENHAIN save time otherwise spent aligning workpieces
parallel with the machine axes. Under either manual or program
control, the TS 3-D Touch Probe simply
contacts two points on a plane side. If the NC control
provides the corresponding function, it can electronically
compensate the measured misalignment. Other NC functions make
it possible to define corners or circle centers as datum.
Workpiece Measurement
and Identification
A TS 3-D Touch
Probe can be used to measure workpieces under program
control, even between individual machining cycles — for
example to compensate tool wear. The NC control can transmit
the results of measurement through the data interface or use
it for in-process control. A 3-D touch probe can also contact
salient points on a workpiece to identify it before machining.
Workpiece Digitizing
Provided that they offer
the required cycles, NC controlled machine tools can use TS
3-D Touch Probes to digitized workpiece models. The
TNC controls from HEIDENHAIN, for example, can convert the
positions thus measured into an NC part program.
TS 220 with cable
transmission: for use with HEIDENHAIN contouring
controls of the TNC 400 series.
TS 230 with cable
transmission: for NC controls with 15-V touch probe
input.
TS 632 with infrared transmission: for both
TNC controls and NC controls with 15-V touch probe input. |
|

TS 220 |

TS 632 |
|
|
TS
220/TS 230 |
TS
632 |
Probe
repeatability |
< 1
µm |
Permissible
stylus deflection
(40 mm stylus length) |
Approx.
5 mm in any direction |
Power
supply |
TS
220: 5 V ± 5 % via NC
TS 230: 10 to 30 V via NC |
2
Lithium-batteries 3,6 V
continuous operation approx. 250 h |
Interface
to NC control |
TS
220:
Signal levels at 5 V rated voltage:
UH >= 2.5 V with – IH <= 20 mA,
UL <= 0.5 V with IL <= 20 mA
TS 230:
Signal levels at 24 V rated voltage:
UH >= 20 V with – IH <= 20 mA,
UL <= 2.8 V with IL <= 20 mA |
Signal
levels at 24 V rated voltage:
UH >= 20 V with – IH <= 20 mA,
UL <= 2.8 V with IL <= 20 mA
via EA receiver unit |
Signal
transmission |
Via
cable |
Via
infrared beam with omnidirectional transmission |
Probing
velocity |
Max.
3 m/min (118 ipm) |
Styli |
With
ball, cylinder and disk tips in various diameters and lengths |
Degree
of protection (IEC 529) |
IP
55 |
|