| Parameter |
Basic Multiplier Specification
|
| Input Frequency |
<
50 kHz |
| Input
Signal Requirements |
Signal
Level |
0º
& 90º 7-16 µApp
w/ 1KWLoad
RM 2 - 8 µApp
w/ 1KWLoad |
|
1
X |
2
X |
| Amplitude
Ratio |
1.0
± 0.2 |
1.0
± 0.1 |
| Duty
Cycle |
180º
± 18º |
180º
± 18º |
| Phase |
90º
± 10º |
90º
± 10º |
| Electrical
Hysteresis |
£0.1
µm |
| Reference
Mark |
Position |
Maximum
positive current flow from RM + w/ positive equal current flow from 0º
90º |
| Width |
From
positive equal current flow of 0º 90º 180º ± 60º |
| Output driver |
75
ALS 194 |
| Max. Output Cable
Length |
Single
Ended 25ft. / Differential 50 Ft. |
| Operating Voltage |
5.0
± 0.25 £ 50mV
Ripple |
| Operating Current |
£
80 mA |
| VOH (High level
output voltage) |
³
2.5, IOH = 20 mA |
| VOL (Low level
output voltage) |
£
0.5, IOL = -48 mA |
| IOH
(High level output current) |
20
mA Max. |
| IOL
(Low level output current) |
-48
mA Max. |
| VOD
(Differential output voltage) |
³
2V, @ 100 ohm load |
| Max. Input Cable Length |
20